I would like to add my solution (which is based on logging cookbook and other articles and suggestions from this thread. However it took me quite a while to figure out, why it wasn't immediately working how I expected. So I created a little test project to learn how logging is working.
Since I have figured it out, I wanted to share my solution, maybe it can be of help to someone.
I know some of my code might not be best practice, but I am still learning. I left the print()
functions in there, as I used them, while logging was not working as expected. Those are removed in my other application. Also I welcome any feedback on any parts of the code or structure.
my_log_test project structure (cloned/simplified from another project I work on)
my_log_test
├── __init__.py
├── __main__.py
├── daemon.py
├── common
│ ├── my_logger.py
├── pkg1
│ ├── __init__.py
│ └── mod1.py
└── pkg2
├── __init__.py
└── mod2.py
Requirements
A few things different or that I have not seen explicitly mentioned in the combination I use:
- the main module is
daemon.py
which is called by __main__.py
- I want to be able to call the modules
mod1.py
and mod2.py
seperately while in development/testing
- At this point I did not want to use
basicConfig()
or FileConfig()
but keep it like in the logging cookbook
So basically, that means, I need to initialize the root logger in daemon.py
(always) and in the modules mod1.py
and mod2.py
(only when calling them directly).
To make this init in several modules easier, I created my_logger.py
which does, what is described in the cookbook.
My mistakes
Beforehand, my mistake in that module was to init the logger with logger = logging.getLogger(__name__)
(module logger) instead of using logger = logging.getLogger()
(to get the root logger).
The first problem was, that when called from daemon.py
the logger's namespace was set to my_log_test.common.my_logger
. The module logger in mod1.py
with an "unmatching" namespace my_log_test.pkg1.mod1
could hence not attach to the other logger and I would see no log output from mod1.
The second "problem" was, that my main program is in daemon.py
and not in __main__.py
. But after all not a real problem for me, but it added to the namespace confusion.
Working solution
This is from the cookbook but in a separate module. I also added a logger_cleanup
function that I can call from daemon, to remove logs older than x days.
## my_logger.py
from datetime import datetime
import time
import os
## Init logging start
import logging
import logging.handlers
def logger_init():
print("print in my_logger.logger_init()")
print("print my_logger.py __name__: " +__name__)
path = "log/"
filename = "my_log_test.log"
## get logger
#logger = logging.getLogger(__name__) ## this was my mistake, to init a module logger here
logger = logging.getLogger() ## root logger
logger.setLevel(logging.INFO)
# File handler
logfilename = datetime.now().strftime("%Y%m%d_%H%M%S") + f"_{filename}"
file = logging.handlers.TimedRotatingFileHandler(f"{path}{logfilename}", when="midnight", interval=1)
#fileformat = logging.Formatter("%(asctime)s [%(levelname)s] %(message)s")
fileformat = logging.Formatter("%(asctime)s [%(levelname)s]: %(name)s: %(message)s")
file.setLevel(logging.INFO)
file.setFormatter(fileformat)
# Stream handler
stream = logging.StreamHandler()
#streamformat = logging.Formatter("%(asctime)s [%(levelname)s:%(module)s] %(message)s")
streamformat = logging.Formatter("%(asctime)s [%(levelname)s]: %(name)s: %(message)s")
stream.setLevel(logging.INFO)
stream.setFormatter(streamformat)
# Adding all handlers to the logs
logger.addHandler(file)
logger.addHandler(stream)
def logger_cleanup(path, days_to_keep):
lclogger = logging.getLogger(__name__)
logpath = f"{path}"
now = time.time()
for filename in os.listdir(logpath):
filestamp = os.stat(os.path.join(logpath, filename)).st_mtime
filecompare = now - days_to_keep * 86400
if filestamp < filecompare:
lclogger.info("Delete old log " + filename)
try:
os.remove(os.path.join(logpath, filename))
except Exception as e:
lclogger.exception(e)
continue
to run deamon.py (through __main__.py
) use python3 -m my_log_test
## __main__.py
from my_log_test import daemon
if __name__ == '__main__':
print("print in __main__.py")
daemon.run()
to run deamon.py (directly) use python3 -m my_log_test.daemon
## daemon.py
from datetime import datetime
import time
import logging
import my_log_test.pkg1.mod1 as mod1
import my_log_test.pkg2.mod2 as mod2
## init ROOT logger from my_logger.logger_init()
from my_log_test.common.my_logger import logger_init
logger_init() ## init root logger
logger = logging.getLogger(__name__) ## module logger
def run():
print("print in daemon.run()")
print("print daemon.py __name__: " +__name__)
logger.info("Start daemon")
loop_count = 1
while True:
logger.info(f"loop_count: {loop_count}")
logger.info("do stuff from pkg1")
mod1.do1()
logger.info("finished stuff from pkg1")
logger.info("do stuff from pkg2")
mod2.do2()
logger.info("finished stuff from pkg2")
logger.info("Waiting a bit...")
time.sleep(30)
if __name__ == '__main__':
try:
print("print in daemon.py if __name__ == '__main__'")
logger.info("running daemon.py as main")
run()
except KeyboardInterrupt as e:
logger.info("Program aborted by user")
except Exception as e:
logger.info(e)
To run mod1.py (directly) use python3 -m my_log_test.pkg1.mod1
## mod1.py
import logging
# mod1_logger = logging.getLogger(__name__)
mod1_logger = logging.getLogger("my_log_test.daemon.pkg1.mod1") ## for testing, namespace set manually
def do1():
print("print in mod1.do1()")
print("print mod1.py __name__: " +__name__)
mod1_logger.info("Doing someting in pkg1.do1()")
if __name__ == '__main__':
## Also enable this pkg to be run directly while in development with
## python3 -m my_log_test.pkg1.mod1
## init root logger
from my_log_test.common.my_logger import logger_init
logger_init() ## init root logger
print("print in mod1.py if __name__ == '__main__'")
mod1_logger.info("Running mod1.py as main")
do1()
To run mod2.py (directly) use python3 -m my_log_test.pkg2.mod2
## mod2.py
import logging
logger = logging.getLogger(__name__)
def do2():
print("print in pkg2.do2()")
print("print mod2.py __name__: " +__name__) # setting namespace through __name__
logger.info("Doing someting in pkg2.do2()")
if __name__ == '__main__':
## Also enable this pkg to be run directly while in development with
## python3 -m my_log_test.pkg2.mod2
## init root logger
from my_log_test.common.my_logger import logger_init
logger_init() ## init root logger
print("print in mod2.py if __name__ == '__main__'")
logger.info("Running mod2.py as main")
do2()
Happy if it helps. Happy to receive feedback as well!